Safety interlock switches, up to 6 contacts

The D4SL-N Safety Interlock Switches by Omron STI is available with up to 6 contacts, can be mounted in any direction and allows users to change the key insertion point without detaching the head.

11/29/2012


The D4SL-N Safety Interlock Switches by Omron STI is available with up to 6 contacts, can be mounted in any direction and allows users to change the key insertion point without detaching the head. Courtesy: Omron STIOmron Automation and Safety's D4SL-N Safety Interlock Switches are available with 4-, 5- or 6-contacts to satisfy many application needs. The IP67-rated D4SL-N can be mounted in four different directions without needing to rotate the head. Two wiring methods minimize wiring time and make possible one-touch attachment and removal. Easy to view LED indicators allow users to quickly check switch status from any direction. D4SL-N safety switches deliver a minimum of 1 million operations and boast a minimum key holding force of 1300 N to maximize the range of potential applications that can benefit from a tough, compact safety switch.

D4SL-N switches are available with two types of wiring. Connector-type wiring models feature a connector cable that reduces the potential for mis-wiring, facilitates fast maintenance, and allows easy switch replacement in the event a switch is damaged. Terminal block-type models include a detachable terminal block to significantly increase wiring efficiency. 

6-contact versions of the D4SL-N safety switch enable users to independently monitor door open/closed status, as well as solenoid on/off status, from a single switch. An optional slide key prevents workers from becoming trapped inside the hazardous area, without having to use a padlock.

Omron STI

www.sti.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me