Rockwell Automation A-B solid-state overload relay: voltage protection, energy monitoring

Allen-Bradley Bulletin 193-EC5 E3 Plus solid-state overload relay provides enhanced motor protection and motor energy consumption information, helps users improve energy efficiency and protect electric motor investment, says Rockwell Automation.

02/25/2010


Allen-Bradley Bulletin 193-EC5 E3 Plus relay from Rockwell  Automation

Allen-Bradley Bulletin 193-EC5 E3 Plus relay from Rockwell Automation

Rockwell Automation Inc. (NYSE: ROK) expanded its overload relay family with the new Allen‑Bradley Bulletin 193-EC5 E3 Plus solid-state overload relay, featuring voltage protection and energy monitoring, the company announced today. Part of the E3 Plus family, the new overload relay combines current and voltage protection with enhanced power monitoring and diagnostic capabilities, helping users improve energy efficiency and safeguard critical electric motor loads. The new overload relay is specially designed for low voltage applications in material handling, water/wastewater, process, petrochemical, and minerals and mining.

"Customers want to be able to monitor consumption patterns and adjust their manufacturing procedures to use electricity more efficiently," said Bill Martin, product manager, Rockwell Automation. "The Bulletin 193-EC5 E3 Plus relay meets this demand by providing current, voltage and power-quality information of a specific motor. This capability in turn helps speed troubleshooting, minimize downtime and reduce energy costs."

Communicating status and diagnostic information using DeviceNet communications with Rockwell Software RSEnergyMetrix software, the new overload relay identifies motors contributing to the monthly peak demand and power factor line items on utility bills. It also assists in activity-based cost accounting and verifying energy-reduction initiatives. In addition, the overload relay is equipped with Allen‑Bradley DeviceLogix Intelligent Component Technology, which integrates logic-solving capability into the overload relay. This provides users with basic digital control when a programmable controller is not available. It also can be used to turn off a motor in the event of lost communications within a control system, the company says.

The new solid-state overload relay also helps protect against voltage issues, such as under voltage, voltage unbalance, phase loss, frequency and phase rotation before the contactor coil is energized, Rockwell Automation explains. While the motor is powering a load, the overload relay protects the motor based on excessive real power (kW), reactive power (kVAR), apparent power (kVA) and power factor. The overload relay accommodates currents ranging from 0.4 A to 860 A, as well as currents up to 5,000 A using external current transformers.

Rockwell Automation says it is the world's largest company dedicated to industrial automation and information. Company headquarters is in Milwaukee, WI. Rockwell Automation says it employs about 19,000 people serving customers in more than 80 countries. www.rockwellautomation.com/components

Also read from Control Engineering :

- Power Protection Devices ;
- Manage information in real time for energy savings, sustainability, say separate reports ;
- I/O Modules ; and
- Machine control channel .

- Edited by Mark T. Hoske, editor in chief, Control Engineering , www.controleng.com.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me