Robotic control alternatives

Open robotic control: As robotic controls advance in capabilities, other options have been emerging for control, including open control software that can be used with multiple vendors’ robots, programmable logic controllers (PLCs), and other non-robotic controllers.

01/22/2014


Intelligrated (upper left and lower right), Southwest Research Institute (upper right), and Beckhoff Automation (lower left) explain various non-traditional methods of robotic control. Courtesy: Sources mentioned and Control EngineeringRobotic controls are advancing in capabilities even as other options have been emerging for control. These include open control software that can be used with multiple vendors’ robots, programmable logic controllers (PLCs), and other non-robotic controllers. Link to each of the three articles at the bottom for more information, additional links and images.

Robots should be doing more than 2 or 3 tasks

If tools aren’t enabling more flexibility in use and expansion of robotics, then we need better tools. That’s what’s behind the ROS-Industrial effort from Southwest Research Institute (SwRI). How does setting up a factory in a day sound?

Robots should be easier to use for more applications, and SwRI established ROS-Industrial, an open source industrial robotic software and working group, to broaden the application of robotics and increase robotic interoperability. ROS stands for robotic operating system. A Dec. 5 quarterly community meeting discussed the general direction of the ROS-Industrial program, reviewed new robotic technologies, and publicized the work and the needs of the community.

PLC-based vs. proprietary robotic controls

For facilities that already use programmable logic controllers (PLCs) for other machine control functions, integrating robotic control into a PLC may be a wiser choice than relying on the controller provided by the robot manufacturer.

As more manufacturing facilities and distribution centers discover the benefits of robotic material handling solutions, they must decide how best to control the robot. While robot original equipment manufacturers (OEMs) offer their own tightly integrated controller, recent developments have enabled control by a programmable logic controller, or PLC.

For facilities that already use PLC-based controls for other machine control functions, integrating robotic control into a PLC may be a wiser choice than relying on an OEM proprietary controller. Speaking robot just got easier.

Industrial PCs ease robotics integration

Hardware and software advancements, such as multi-core processors and industrial Ethernet fieldbus technology, are enabling engineers to integrate cost-effective robotic solutions with motion control, communications, and human-machine interfaces. 

Adding open-control hardware and software to the convergence of well-known controls principles makes it possible to create machine designs that feature seamlessly integrated robots. This results in game-changing advantages for machine builders and manufacturers and the ability to integrate robot technology into more applications, including those that are traditionally among the most cost-sensitive.

The cost-saving benefits that make this possible include: reduced wiring, network and software platforms that are shared with the overall machine automation system, and a significantly reduced machine footprint. This has led to higher performance mechatronic and robotic solutions, including product packaging with variable product flow and complex material handling lines.

- Control Engineering, January 2014 North American print and digital edition



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me