Robot designed to handle payloads up to 8 kg at 100 cycles per minute

The 8 kg model of ABB Robotics' IRB 360 FlexPicker line handles up to 100 cycles per minute and has improved motion tuning as well as handle higher payloads.

07/31/2013


The 8 kg model of ABB Robotics' IRB 360 FlexPicker line handles up to 100 cycles per minute and has improved motion tuning as well as handle higher payloads. Courtesy: ABBABB Robotics has added an 8 kg model to its IRB 360 FlexPicker line, supplementing the existing 1 kg and 3 kg models. The 8 kg version of the IRB 360 robot has been re-engineered to handle higher payloads and improved pick-and-place performance. The new design includes a redesigned carbon fiber arm-set, a new delta plate designed to handle larger weights and inertias, and improved motion tuning. It has also been engineered to handle up to 100 cycles per minute.

The 8 kg FlexPicker is designed for operation in sanitary environments, and the stainless steel IPK69 rated model withstands the most stringent cleaning operations associated with sanitary product handling. Multiple variants of work envelopes are available, all with environmental protection options to meet most application requirements. 

In addition to handling flow wrapped products, the IRB 360 8 kg FlexPicker is ideal for the direct picking and placing of unwrapped food products and pharmaceuticals into primary wrappers; loading meat products into trays; and kitting of personal care products and medical devices into blister packs.

ABB Robotics

www.abb.com/robotics 

- See more Control Engineering discrete manufacturing products.

- See other Control Engineering robotic coverage.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me