RF vector signal analyzer for demanding automated test applications

National Instruments' NI PXIe-5665 is a 3.6 GHz RF vector signal analyzer features phase noise, average noise level, amplitude accuracy and dynamic range.

05/06/2011


National Instruments has introduced the NI PXIe-5665, a 3.6 GHz RF vector signal analyzer (VSA) that delivers high RF performance in a cost-effective PXI form factor. The new VSA features phase noise, average noise level, amplitude accuracy and dynamic range. The VSA’s PXI platform also facilitates peer-to-peer streaming; includes a flexible multiple input, multiple output (MIMO) architecture for phase-coherent measurements; and offers measurement speeds that are at least five times faster than traditional rack-and-stack instruments – all of which make it ideal for demanding automated RF test applications.

The VSA combines the new NI PXIe-5603 downconverter with the new NI PXIe-5653 local oscillator synthesizer and the NI PXIe-5622, a 150 MS/s intermediate frequency (IF) digitizer. This combination creates an ideal solution for spectrum and wideband vector signal measurements over a frequency range from 20 Hz to 3.6 GHz with analysis bandwidths up to 50 MHz. The new VSA features an exceptionally low phase noise of -129 dBc/Hz at a 10 kHz offset at 800 MHz, an average noise level of -165 dBm/Hz, a third-order intercept point of +24 dBm and absolute amplitude accuracy of ±0.10 dB. These specifications make the NI PXIe-5665 the highest performing instrument in its class.

For modulated signal analysis, the VSA’s unique onboard self-calibration tool makes it possible to achieve an IF amplitude response of ±0.15 dB and IF phase linearity of ±0.1 degree. This accuracy facilitates exceptional error vector magnitude performance of less than 0.21% for a 256-QAM signal. The VSA’s flexible, modular architecture expands to provide phase-coherent acquisition for MIMO test, as well as a 20 GHz/s scan rate and peer-to-peer streaming for efficient spectrum monitoring. Additionally, engineers can operate the NI PXIe-5665 using its RF list mode function to deterministically step through a user-defined set of RF configurations using internal timing or an external trigger to significantly reduce test time.

Because the NI PXIe-5665 joins a product line of more than 1,500 software-defined PXI modular instruments, engineers can mix and match the VSA with a variety of modules and control an entire automated test system with NI LabVIEW graphical system design software. This makes PXI systems ideal for a multitude of automated test applications. Engineers also can fully take advantage of the VSA’s software-defined performance with RF software toolkits for LabVIEW, NI LabWindows/CVI and .NET to test the latest RF and wireless communication standards including GSM/EDGE, WCDMA, LTE, WLAN and WiMAX.

www.ni.com

National Instruments

- Edited by Amanda McLeman, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.