Remote panel connections up to 100 m

At Hannover Messe Beckhoff presented its CP-Link 4, new connection technology for remote panel operation over distances as far as 100 m from the industrial PC. One CAT 7 cable transfers video signals, USB, and power. Cable and assembly costs are reduced.

04/11/2013


CP-Link 4 – The One Cable Display Link: The optimum combination for remote panel operation over distances of up to 100 m is provided by Beckhoff multi-touch panel and CP-Link 4, the company said at 2013 Hannover Fair. Courtesy: Beckhoff AutomationBeckhoff CP-Link 4 was shown at 2013 Hannover Fair. It is new connection technology for remote panel operation over distances as far as 100 m from the industrial PC, the company said. Video signals, USB, and power are transferred via a standard CAT 7 cable. Cable and assembly costs are reduced.

Using CP-Link 4, the Beckhoff CP29xx-0010 multi-touch built-in panels and the CP39xx-0010 multi-touch panels for mounting arm installation can be operated up to 100 m away from the PC. It transfers digital visual interface (DVI) and USB via a CAT 7 cable. The CU8802 CP-Link 4 sender box is connected to the PC via DVI and USB, or else the C9900-E276 PCIe module for CP-Link 4 is installed in the PC. Power supply for the control panel also can be provided via the CP-Link 4 display link. The CU8803 CP-Link 4 sender box is used instead of the CU8802 or the PCIe module. The control panel remains unchanged. The CU8803 sender box provides power to the control panel via the CAT 7 cable, which also transfers DVI and USB. The power supply socket of the panel is not used.

 - Edited by Mark T. Hoske, content manager, CFE Media, Control Engineering, and Plant Engineering, mhoske@cfemedia.com.

ONLINE

See also information on Beckhoff Automation CP-Link 3.

Beckhoff Automation PDF describes other recent introductions and products.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me