Refrigerant safety standards published

ASHRAE’s refrigerants-related standards, Standard 34: Designation and Safety Classification of Refrigerants, and Standard 15: Safety Standard for Refrigeration Systems, have been published.


The 2013 editions of ASHRAE's major refrigerants-related standards, incorporating 41 new addenda, have been published.

Requirements in ANSI/ASHRAE Standard 34-2013, Designation and Safety Classification of Refrigerants, and ANSI/ASHRAE Standard 15-2013, Safety Standard for Refrigeration Systems, complement each other in that Standard 34 describes a shorthand way of naming refrigerants and assigns safety classifications based on toxicity and flammability data. Standard 15 establishes rules for safe application in equipment and systems when the refrigerant classification system. ASHRAE sells the standards as a set.

Standard 34-2013 contains the 2010 standard and 36 published addenda. Among the key changes incorporated into the standard are:

  • Assignment of designations and safety classifications for one new single compound refrigerant and 14 new refrigerant blends.
  • Changed the refrigeration concentration limits (RCL) values of 19 refrigerants listed in the 2010 standard to comply with more current methodology.
  • Changed the flammability safety classifications of four refrigerants from Class 2 to Subclass 2L, based on optional burning velocity measurement data.
  • Added Toxicity Code Classification assignments for 18 refrigerants that had been unassigned in the 2010 standard.
  • Clarified methodology for conducting flammability tests and for determination of fractionated compositions for flammability testing.
  • Updated methodology by which the heat of combustion is calculated for refrigerant blends, and provided heat of combustion calculation examples for refrigerant blends.
  • Defined requirements that applicants shall provide evidence of the existence of an azeotropic blend, if requesting an R-500 series designation.
  • Modified sections of the standard to add bubble-point and dew-point definitions and test conditions, clarified applicant documentation requirements related to GLP compliance and added critical pressure data and specific volume calculation methodology for applicant submissions.

Standard 15 contains the 2010 standard plus five published addenda. Key changes to the standard include:

  • Clarification of the location requirements for machinery room mechanical ventilation.
  • Clarification that design pressure is expressed in terms of relative pressure or gauge pressure (not absolute pressure).
  • Wording to ensure the standard more closely harmonizes with the 2012 International Mechanical Code (IMC) section 1101.10.

Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Developing lighting solutions; Designing lighting systems; Integrating fire alarm and HVAC systems
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me