Radiant heating/cooling mat

Finalist in HVAC/R in Consulting-Specifying Engineer's 2011 Product of the Year competition

05/09/2011


The Uponor Radiant Rollout Mat is a prefabricated, prepressurized network of cross-linked polyethylene (PEX-a) tubing designed for installations of large commercial radiant heating and cooling applications. The mat consists of Wirsbo hePEX (oxygen barrier) or Uponor AquaPEX (nonbarrier) PEX—a tubing connected with ProPEX engineered plastic (EP) fittings, which are safe for burial in the slab and offer fast on-site customization. With the radiant rollout mat, workers simply roll out tubing and fasten it down. A double-mat option is available, and the product uses acetal polymer support braces every 7 ft and predrilled holes for stake and anchor supports.

www.uponor-usa.com

View HVAC/R finalists



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me