Radar level transmitters

Endress+Hauser's FMR5X radar level transmitter can measure level or volume of liquids and bulk solids products in metal or plastic tanks, stilling wells or other vessels up to 131 ft.

03/20/2014


Endress+Hauser's FMR5X radar level transmitter can measure level or volume of liquids and bulk solids products in metal or plastic tanks, stilling wells or other vessels up to 131 ft. Courtesy: Endress+HauserEndress+Hauser's Micropilot FMR5X series of free space radar level transmitters can be used to measure level or volume with a built-in 32-point strapping table. The liquids can be measured in metal or plastic tanks, stilling wells, bypass chambers or other vessels up to 131 ft high with standard units or 197 ft with enhanced dynamics option. The instrument can also be used to detect minimum or maximum levels to prevent overfilling or empty tanks in addition to continuous monitoring of the level.

The FMR5X measures the distance from the process connection to the product surface and is equipped with multi-echo tracking algorithms that ensure that interference echoes are not interpreted as level echoes. Multi-echo tracking uses self-learning algorithms that build short term and long term history to check the echoes for plausibility and increased reliability.

A linearization table of up to 32 points can be entered either manually or semi-automatically. This function provides a linear 4-20mA output signal for spheres, horizontal cylindrical tanks and vessels with a conical outlet. Linearization can also be used to convert the level measurement into volume or mass engineering units.

Endress+Hauser

www.us.endress.com 

- Edited by CFE Media. See more Control Engineering sensor and actuator products.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me