Put your meter where your mouth is

Proponents, advocates, designers, and owners of green or sustainable buildings describe building sizes, construction costs, and how beneficial they are—especially from an energy or emissions perspective.

05/01/2008


Proponents, advocates, designers, and owners of green or sustainable buildings describe building sizes, construction costs, and how beneficial they are—especially from an energy or emissions perspective. Trade publications and the popular press abound with such accounts in articles and press releases. Largely absent from pronouncements and publications are factual, measured data to support these claims, even when these data are or can become readily available from meters, submeters, energy management systems, and data loggers.

Frequently, these claims tout how green buildings are some percentage lower or better than the prevailing building code or ANSI/ASHRAE/IESNA Standard 90.1. Yet those claims often are based on models generated during the design phase, not meters, even though the building is occupied. How can readers compare green-building claims with their own buildings or with national statistics, such as the U.S. Dept. of Energy's Commercial Buildings Energy Consumption Survey (CBECS)?

With green design implicitly or explicitly becoming common or code, this is more than a rhetorical question. The buildings' community is owed more performance data than what they're seeing. More specifically, designers and owners need to document and report their performances before we further ensconce green design principles and methodologies explicitly or implicitly in building codes and standards.

Consider, for example, the Environmental Protection Agency's Energy Star program for buildings, whereby if a building's metered energy consumption, verified by a professional engineer, is in the lowest quartile of energy consumption (based on CBECS data), it earns an Energy Star label. Thus, buildings 50 and 100 years old earn an Energy Star label without doing anything, What, then, can an engineer learn after reading a case study about an Energy Star building that does not report its actual energy consumption?

Green and sustainable rating systems, such as the USGBC LEED program, claim their certified buildings are “more energy efficient” than conventional buildings. A recent report published by the New Buildings Institute found that, on average, 121 sampled LEED NC buildings with a minimum of 12 months of metered data are about 25% more energy efficient than CBECS buildings. That same study found that less than half of the sampled LEED NC buildings would not have earned an Energy Star rating, and that a quarter of them used more energy than the average existing U.S. building. The report states, “Further investigation of the reasons for these shortfalls holds potential for significant further improvements of overall LEED performance.” Such investigations would benefit from more published data.

Here's what would help: In green building case studies, include the actual metered energy consumption data for 12 consecutive months, along with those features and uses of the building that are unusual, such as hours of operation or energy-intensive functions. A simple table of the factual metered data, along with the size in square feet should suffice. It should be assumed that the data includes all of the energy used, including HVAC and hot water, whether purchased from utilities, or generated on-site. If all or part of the energy is not metered or measured, that should be stated, with reasons for the omission. Recognizing that data from the first year may not always be representative; metered data from the second to fifth years are preferred.


Author Information

Spielvogel is a consulting engineer in King of Prussia, Pa. An ASHRAE Fellow, Spielvogel's practice includes evaluating the metered energy performance of buildings nationally. He also is an expert witness in disputes on these issues and he lectures to industry construction groups.




No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me