Project profile: Energy-efficient K-12 school

The building’s MEP design follows a city-wide effort to reduce consumption of fuel and electrical power and is designed to be 50% more efficient than energy code requirements.

10/02/2014


Project Name: Metropolitan Business Academy

Building exterior. Courtesy: S/L/A/M Architecture.Project Type: New construction

Engineering Firm: OLA Consulting Engineers

Architect: S/L/A/M Collaborative

Building Type: K-12 School

Location:
New Haven, CT

Timeline:
December 2006 - June 2011



Building details

The new 4-story Metropolitan Business Academy is an 86,000 sq ft building that is home to students in grades 9 through 12 in New Haven, CT. The building contains 5 full computer labs, a first floor atrium space and a cafeteria flooded with natural light, video editing room, cone-shaped 105-seat lecture hall with video conferencing, teacher's resource room, and classrooms with LCD projectors.


Sports center. Courtesy: S/L/A/M Architecture.Project details
The building's MEP design follows a city-wide effort to reduce consumption of fuel and electrical power and is designed to be 50% more efficient than energy code requirements. Energy efficient features include:

  • Electrical: Low lighting power density and advanced lighting controls help achieve an almost 66% reduction in energy use intensity.
  • Mechanical: High efficiency chiller plant with thermal storage, high efficiency boiler plant, demand controlled ventilation, and bi-polar ionization air treatment.
  • Fire Protection and Plumbing Services: Sprinkler hydraulic calculations, smoke dampers, and a wet pipe system throughout. Plumbing services included back flow preventor, toilet rooms, kitchen, domestic water heating systems, fuel systems, and roof drainage. 

 

Student commons. Courtesy: S/L/A/M Architecture.Challenge and solution
Since this project is located near the intersection of two interstate highways and a heavily traveled State highway, the air quality for outdoor air intake is very poor. In order to properly treat the ventilation air and provide acceptable indoor air quality a bi-polar ionization air treatment system was installed allowing outdoor air ventilation rates to be reduced and additional energy saved.

Project results
One year of utility data, energy efficiency information, or other data prove the project's success. The design phase energy model calculated an energy use intensity (EUI) of 44.0 kBTU/sq ft for the building. After being constructed and operating for a year, the actual building energy use intensity as indicated by utility meter readings for the year was 45.9 kBTU/sq ft, a difference of only 4.3% of the theoretical model.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me