Project profile: Data center with eNotify system

Cleveland State University's new data center incorporates automatic monitoring system, eNotify, to prevent system downtime.

11/03/2014


Project name: Cleveland State University data center

Project type:
Preventive maintenance support

Engineering firm:
Eaton

Building type:
Educational facilities, data center

Location:
Cleveland, OH

Timeline:
2006 - present



Building details

Located in the heart of Cleveland, Ohio, Cleveland State University encompasses 85 acres and 40 buildings. Cleveland State's 5,000 sq ft data center hosts a wide variety of equipment that keep essential services operational throughout the campus. Vital functions such as financial aid, accounts payable and receivable, and other critical services all pass through the university's data center and require a unique power backup solution for continues uptime to that broad range of equipment.

Project details

To keep Cleveland State's vital equipment up and running, the project team designed a solution powered by Eaton's 9390 uninterruptible power system (UPS). With a double-conversion, 9390 UPS safeguards the data center equipment against outages, sags, surges, spikes, brownouts, line noise, frequency variation, switching transients and harmonic distortion. The UPS service includes technicians delivering 24 hour, seven-day-a-week service support with corrective maintenance coverage, remote monitoring advance response service, annual power protection audit assessment of power protection and load configuration.

With eNotify system, which provides real-time monitoring of more than 100 UPS and battery alarms. Cleveland State receives monthly reports that detail UPS status and information such as voltages, loads, temperature and humidity, as well as a summary of the top 10 performance and environmental parameters, battery events, availability percentage and comparative status against recommended specification. eNotify includes remote monitoring of both the UPS and the batteries at all times by Eaton service technicians, a level of attentiveness that allows many issues to be resolved remotely. eNotify automatically dispatches a technician directly to the CSU data center if an emergency situation is detected.

Project results

Meet uptime requirements with ease. Create UPS service configurations for all the applications. Annual preventive maintenance checks and battery preventive maintenance inspections 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me