Product Exclusive: United Electric Controls TX200H, HART 7 smart pressure transmitter

Designed for upstream oil and gas applications, the TX200H simplifies field adjustments and communicates asset management data via the latest HART 7 specification. This is an April 2011 Control Engineering Product Exclusive.

04/18/2011


United Electric ControlsUnited Electric Controls introduces the TX200H, a HART 7 smart pressure transmitter designed for upstream oil and gas applications. The TX200H provides simplified field adjustments while reliably communicating asset management data using the latest HART 7 specification.

A flexible 10:1 turndown on pressure ranges from 0 to 15 psi up to 0 to 25,000 psi allow users to range the transmitter as application requirements change while reducing inventory levels through model reduction. The TX200H real-time diagnostics also reduce maintenance costs by reporting device health status and process performance, alerting users to potential problems to troubleshoot before escalation occurs. 

TX200H is constructed of 316 stainless steel, welded and hermetically sealed to meet enclosure type 4X and IP66 requirements. Its rugged, compact design lends itself to being mounted directly onto the process or panel mounted within a control panel. Standard approvals include cULus for Class I, Div. 1 and 2, Zone 1 and ATEX Ex d and Ex tD hazardous areas. It is CE compliant to PED and EMC directives.   

Integrating the TX200H into most process systems is simple. Since HART communication is superimposed over the 4-20 mA signal, the TX200H can use existing wiring as an upgraded, drop-in replacement for a standard analog 4-20 mA transmitter. A user may easily communicate with the TX200H using a handheld device or a PC equipped with commercially available software.

www.ueonline.com

United Electric Controls



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me