Product Exclusive: Single airflow sensor

Festo SFAM 90 Flow Sensor reduces energy costs and improves productivity and quality. This is a May 2011 Control Engineering Product Exclusive.

05/25/2011


Festo SFAM 90 Flow Sensor reduces energy costs and improves productivity and quality. This is a May 2011 Control Engineering Product Exclusive.Festo’s new SFAM 90 airflow sensor can precisely monitor an entire machine’s airflow to detect conditions that are wasting energy—conditions that also indicate pneumatic valves and actuators are not performing to specifications. With this timely diagnostic information, maintenance personnel can quickly react to problems before those become major cost, quality, or productivity issues.

The modular SFAM 90 can be operated as a stand-alone unit or combined with the Festo MS series air preparation systems and pressure sensors. Using the combined configuration provides an enterprise with an advanced, cost-justified, energy-saving, productivity-enhancing, and preventive maintenance solution for pneumatics. 

The SFAM 90 provides absolute flow information and accumulated air consumption measurement. It features an adjustable consumption-based switching impulse for accumulated air consumption measurement via the switching output. It can provide precise information even when flow conditions are fluctuating and unreliable. With its highly dynamic response of 1:100, the sensor covers an extensive measuring range with a specified accuracy.

The large, illuminated LCD display increases operational safety and makes flow rate and consumption values easy to read. Values outside of the measuring range are shown as flashing figures on the display, and the color of the display changes. Threshold values can be identified over long distances or if the sensor is inaccessible. 

NPN/PNP can be switched via software. Having either NPN or PNP in one unit reduces the need for stocks of components, cuts costs, and results in fewer purchasing and design decisions. Values shown on the display can be set for DIN1343, ISO 2533, or ISO 6358 standards. Values can be filtered and averaged independently of the analog output in the case of high measurement dynamics. There is also simple switching between consumption and flow data indicators.

The SFAM 90 is compact, which makes for flexible installation. The unidirectional flow sensor offers a choice of flow direction left to right or right to left. It is plug and play, with clear and fast menu navigation and manual consumption measurement with start/stop and reset functionality.

Subassemblies available

Festo offers pre-assembled solutions for compressed air preparation, flow, and pressure monitoring. These solutions come with one part number, which simplifies the design and purchasing process. The subassemblies are supplied ready to install. Festo also supplies compressed air system accessories, such as tubing and fittings. Tubing materials appropriate to the environment prevent chemical, physical, and microbial damage. Festo tubing can be hydrolysis-resistant, flame-retardant, heat-resistant, antistatic, and suitable for use in the food industry. Fittings use Festo modern sealing rings and support functions to ensure leak-proof and reusable screw connections, the company said.

www.festo.com/us Festo



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me