Pressure sensor family introduced

Balluff's BPS series of pressure sensors come with IP 67 protection and have 11 pressure range versions for monitoring in process media in factory automation.

09/15/2011


Balluff introduced BPS, a newly developed series of pressure sensors with IP 67 protection for use in gaseous and liquid media. The devices feature a ceramic load cell, simple installation, high operating comfort and high precision. A large, bright and easily visible display ensures immediate status overview. This shows not only the current system pressure in bar, mbar, PSI and MPa, but also features fast and simple configuration of the sensors according to the VDMA standard, using 2 keys and intuitive menu guidance.

With 11 pressure range versions the BPS sensors cover all the important ranges from -1…0 bar up to 0…600 bar for monitoring process media in factory automation. Typical applications include hydraulics monitoring as well as pneumatics equipment. The new Balluff pressure sensors, available in the standard model with plastic housing and in the high-end version with stainless steel, offer either two switching points or one switching output plus analog channel (0…10V or 4…20mA).

Thanks to their compact design the sensors can be easily located in the control cabinet without taking up valuable space. The display with operating panel and electrical connection can be rotated independently of each other by 320° with respect to the flange. Adapting to different process terminations using G ¼ internal threads is accomplished using optional adapters in various sizes and styles.

The high-end models, which have stainless steel housing and expanded temperature range, were especially designed for demanding applications in harsh environments, making them ideal for use with wind power turbines, offshore installations as well as HVAC technology.

www.balluff.com

Balluff Inc.

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.