Pneumatic air supply pressure regulation and filtration products

Pneumatic products are designed to work in stand-alone applications, but modular design enables field assembly for combining additional components.

09/17/2010


AutomationDirect has added to its Nitra line of products for pneumatic air supply pressure regulation and filtration applications. While each product series is designed to work in stand-alone applications, the modular design enables field assembly for combining additional components.

AF Series particulate and moisture separation air filters are available with 1/8-in. to 1-in. NPT female port sizes and either a semi-automatic or automatic drain. Polycarbonate bowls are standard on 1/8-in. through 1/2-in. sizes, while metal bowl guards are provided on 1/4-in. through 1/2-in. sizes. The 1/4-in. and 1-in. sizes feature all-metal bowl construction with sight gauges. Nitra AR Series pneumatic air pressure regulators are available with adjustable pressure ranges of 20-130 psi or 7-60 psi.

AFR Series combines particulate/moisture separation air filters and adjustable pressure regulators, all in a single convenient unit. Available in 1/8-in. through one-in. sizes, the pressure regulator features a locking pressure adjustment knob, integral pressure gauge with adjustable pressure ranges of 20 -115 psi.

AL Series mist-type air lubricators are available with 1/8-in. to one-in. NPT female port sizes and a lubrication rate adjustment with sight gauge. The 3/4-in. and one-in. sizes feature all-metal bowl construction with sight level gauges. Replaceable 40 micron filter elements are standard.

ARV pneumatic manual shut-off pressure relief valves are available with 1/8-in. to 1/2-in. female ports. The three-way, two-position design is used to shut off upstream pressure and relieve downstream pressure, and the manually rotated knob can be locked out with the included padlock.

Three new series of directional control solenoid valves are also part of the complete Nitra line.

www.automationdirect.com/pneumatic-parts

 www.automationdirect.com

AutomationDirect

AutomationDirect is a CSIA member as of 2/26/2015

- Also from Control Engineering:

 

Get AutomationDirect DINnector products in smaller quantities

PLC programming software now free

Motor monitoring relays with user-adjustable settings


- Edited by Renee R. Bassett for Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me