PLC for extreme environments

The AC-500 XC PLC from ABB is designed to operate in extreme temperatures and has extended immunity against corrosive elements and electric shock.

08/30/2013


The AC-500 XC PLC from ABB is designed to operate in extreme temperatures and has extended immunity against corrosive elements and electric shock. Courtesy: ABBABB's AC500-XC PLC is protected against a wide variety of threats including high and low temperatures, high humidity, low air pressure, salt mist and hazardous gases, and vibration and shock. This helps eliminate the need for sophisticated protective enclosures with special seals, HVAC, shock absorbers, EMC protection and other safety features.

The embedded protection features ensure that AC500-XC PLC based control systems stay functional and reliable even when operating in hostile environments. Such conditions can be found in many common automation applications including mines, tunnels, vessels, cranes, water and wastewater plants, offshore platforms, wind turbines, solar trackers and weather and navigation stations.

Embedded environmental protection opens up extensive applications potential for the ABB AC500-XC. Extended temperature operation allows the PLCs to operate in temperatures from -30 to +70 °C. Circuit boards are conformally coated to protect against high humidity levels. The PLC has extended immunity against salt mist and atmospheres with corrosive gases such as H2S, SO2, CL2 and NO2.

High levels of vibration and shock can be tolerated, with accelerations up to 4 g from random vibrations up to 500 Hz, or 2 g  from sinusoidal vibration. The PLC is capable of operating at altitudes up to 4,000 m. It also offers extended EMC protection against voltage surges and fast transients, as well as electrostatic discharge.

ABB

www.abb.us 

- See more Control Engineering controller products.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me