PLC Ethernet adapter serves as micro PLC alternative

The FX3U-ENET-ADP by Mitsubishi Electric designed to be an alternative to micro PLCs to connect PLCs and HMIs. It also uses GX Works to create a direct connection and synchronizes a PLC's internal clock.

08/27/2012


The FX3U-ENET-ADP by Mitsubishi Electric designed to be an alternative to micro PLC's to connect PLCs and HMIs. It also uses GX Works to create a direct connection and synchronizes a PLC's internal clock. Courtesy: Mitsubishi ElectricMitsubishi Electric Automation's Ethernet adapter for its FX3 Series PLCs, the FX3U-ENET-ADP, can be a cost-efficient alternative to micro PLCs to connect equipment such as PLCs, HMIs and personal computers. It has a built-in data monitoring tool so users can view real-time status and current data values of their equipment.

The FX3U-ENET-ADP features easy setup through standard programming software, four-channel communications for access to a wide range of devices, and an embedded data monitor for viewing network status using just a web browser. The adapter interfaces easily with other control systems and connects with most modular machine components to deliver detailed information about network conditions. It uses GX Works2 to create a direct connection without setting any IP addresses, and automatically synchronizes a PLC’s internal clock to an SNTP time server.

Mitsubishi Electric Automation Inc.

www.meau.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me