Pipe hangers and supports standards updated

The Manufactures Standardization Society has published a comprehensive standard practice for pipe hangers and supports.

11/05/2009


 

The Manufactures Standardization Society (MSS) has published a newly revised and enhanced Standard Practice, SP-58-2009, Pipe Hangers and Supports - Materials, Design, Manufacture, Selection, Application, and Installation.

This comprehensive Standard Practice combines all of the content of five Pipe Hanger and Support standards into a single document. MSS SP-58-2009 will serve as a complete guide for pipe hanger and support design, manufacture, selection, and installation, enabling the user to specify a minimum level of acceptance for pipe hanger design and performance, in addition to defining the types of hangers and supports.

MSS SP-58-2009 includes all of the information from ANSI/MSS SP-69, Selection and Application; MSS SP-77, Guidelines for Pipe Support Contractual Relations; MSS SP-89, Fabrication and Installation Practices; and MSS SP-90, Guidelines on Terminology for Pipe Hangers and Supports.

The scope of this revised Standard Practice:

• Establishes the material, design, fabrication, and inspection criteria to be used in the manufacture of standard types of pipe hanger components
• Establishes the allowable stress values for materials used in standard types of pipe support components and unique hanger design assemblies
• Establishes minimum design load ratings for rigid pipe hanger assemblies
• Presents the recommended practice for the selection and application of pipe hangers and supports for all service temperatures
• Establishes recommended procedures for detailing, fabrication, and installation of pipe hangers and supports
• Serves as a pipe hanger and support specification for selection and application
• Serves as a guide to proven industry practice during engineering design and writing of job specifications covering the hanging, supporting and controlling the movement of piping systems
• Provides the erector with information on types of hanger and support components to be used for specific application and installations, where such information is not otherwise provided
• Serves as a companion document to MSS SP-127 which provides recommendations for the design, selection, and application of bracing for piping systems subject to seismic- wind - dynamic loading.

The content of this Standard Practice provides an effective, clear, and non-exclusive specification that benefits the industry as a whole and provides a basis for common practice by manufacturers, users, and the general public.

Order information is available online.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me