pH probe, sensor

The FU24 is a 'four in one' pH sensor

04/12/2012


The FU24 is a new ‘four in one’ pH sensor designed to offer virtually maintenance-free operation and long sensor lifetime – especially in harsh applications involving severe temperature and pressure fluctuations. The sensor incorporates a bellows system, which automatically compensates for the effect of pressure fluctuations. Such pressure variations can be highly detrimental to sensor operation, as they can initiate a pumping effect resulting from the expansion and shrinkage of the gel or liquid inside the sensor. The outcome is that the process liquid will start to ingress into the sensor and the reference voltage – and hence the pH measurement - will start to drift. In the FU24 sensor, pressure fluctuations are automatically compensated by the built-in bellows up to 10 bar, making the sensor virtually insensitive to pressure variations. A positive overpressure maintained by the tension in the bellows generates a steady flow out of the sensor. 

Yokogawa Corporation of America 

www.yokogawa.com/us



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me