‘Option card' connects Danfoss VLT AutomationDrive to Profinet-based networks

MCA120 features a built-in Web server for remote diagnostics and visual confirmation of basic drive parameters, as well as an e-mail, says Danfoss Drives.

Renee Robbins

03/10/2010


Danfoss Profinet option card  for VLTR Automation Drive
The Danfoss Drives VLT Profinet MCA120 Option Card, expanding the Ethernet communication capabilities of its VLT AutomationDrive to Profinet-based networks. This option card handles a single connection with an Actual Packet Interval down to 1 ms in both directions, positioning it among the fastest performing Profinet devices in the market, according to the company.


The MCA120 features a built-in Web server for remote diagnostics and visual confirmation of basic drive parameters, as well as an e-mail notifier that can send a message to one or more recipients should certain warnings or alarms occur, and/or are cleared.


Supported application protocols include Profinet for control and parameter setting, HTTP (Hypertext Transfer Protocol) for diagnosis via the built-in Web server, and SMTP (Simple Mail Transfer Protocol) for email notification. The Profinet Option Card also supports DHCP (Dynamic Host Configuration Protocol) for automatic IP address configuration, FTP (File Transfer Protocol) for file up- and download, TSC (Transparent Socket Channel) for easy access to drive configuration data from Danfoss' MCT 10, and DCP (Discovery and Configuration Protocol) for making topology and neighborhood recognition, and IP-address assertion, possible from a PLC. Sales information available via e-mail.

- Edited by Renee Robbins, senior editor

Control Engineering News Desk
More Industrial Networks news from Control Engineering
More Motors and Drives news from Control Engineering



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.