Optical bypass relay

The OBR40 optical bypass relay by Belden is designed for harsh environments and both ring and bus topologies as well as an IP30 protection rating.

07/08/2013


The OBR40 optical bypass relay by Belden is designed for harsh environments and both ring and bus topologies as well as an IP30 protection rating. Courtesy: BeldenBelden's OBR40 optical bypass relay is designed for harsh environments. The relays increase the availability of fiber-optic Ethernet networks by ensuring that they remain operational despite power failures at one or more switches. These relays are designed for ring and bus topologies. 

The bypass relay also supports at-will activation of the bypass function for maintenance or selective shutdown of parts of the network. For example, when the wind gets too strong in a wind park, or when maintenance work is needed, one or more turbines can be easily taken out of the network without affecting the connections of the remainder.

The bypass relay is available with ports that support three different fiber types (multi-mode 62.5/125 µm, multi-mode 50/125 µm, single-mode 9/125 µm). The switching threshold is adjustable via a DIL switch over a range of 1V to 32V. In addition, a switch-on delay (adjustable for intervals of up to 75s) allows the switch's boot process to complete so that no data packets are lost or delayed when a switch comes back on line. The bypass relay also features an IP30 protection rating, an operating temperature range of -40°C to +70°C, and a redundant 24 VDC power supply. The 115 x 61 x 113 mm metal housing is DIN-rail mountable. LEDs on the front panel indicate the status of the device and network.

Belden

www.belden.com 

- See more Control Engineering industrial network products.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me