Opposing-port tee

The ProPEX EP opposing-port tee was developed for PEX hydronic heating and cooling applications with back-to-back installation-spacing constraints, such as vertical riser applications, vertical hi-stack fan coils, and heat pumps.

04/13/2017


Uponor ProPEX EPThe ProPEX EP opposing-port tee was developed for PEX hydronic heating and cooling applications with back-to-back installation-spacing constraints, such as vertical riser applications, vertical hi-stack fan coils, and heat pumps. One opposing-port tee does the job of four fittings to change piping direction in a confined space, making it a time-, cost-, and labor-saving solution for engineers, installers, and building owners. The tee features the ProPEX fitting system, a method that uses the shape memory of PEX tubing to make a strong, reliable, and watertight connection with a single tool. The ProPEX tee is available in 1-, 1.25-, 1.5-, and 2-in. flow-through sizes with 0.75-in. outlets.

Uponor, http://uponor-usa.com

This product is a Finalist in the Consulting-Specifying Engineer 2017 Product of the Year program. View more Finalists and cast your vote at www.csemag.com/votepoy (voting closes June 30, 2017).



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me