One step to a better maintenance plan

Before adopting a proactive maintenance culture, conduct an electrical system analysis

Frank Waterer, Schneider Electric Engineering Services

01/17/2012


Transitioning from a reactive “fix only what is broken” culture to creating a proactive routine preventive maintenance model is a long but sound business process. Before any maintenance program is initiated or contracted, it is strongly recommended that the facility’s management contract and commission the services of a licensed professional electrical engineer to perform short circuit analyses, a time/current coordination study, and an arc flash analysis, of the entire electrical power distribution system.

 

These studies will ensure that the existing electrical equipment is properly rated, set and labeled. There is wasted value in spending limited maintenance budget and resources to clean, maintain, and service electrical equipment that is later determined as needing to be replaced or removed from service.

 

In some circumstances, a Power System Risk Assessment is recommended prior to beginning a preventive maintenance program. The Risk Assessment can reveal safety concerns, poorly maintained equipment, as well as the negative affects of harsh environmental conditions as elevated temperature, moisture, dirt, polarized dust and other contaminates on electrical equipment.

 

A risk assessment provides valuable information concerning the “present state” of an electrical power distribution system and its associated equipment, its functionality, and reliability relative to the present needs of a facility’s operations. (Note: Business functions and operations change much faster than power distribution systems. A 20th century power distribution system might be inadequate to the needs and requirements of 21st century sensitive electronic loads.)

 

A key feature of a Power System Risk Assessment is the Hazard Vulnerability Analysis, which prioritizes the recommended corrective actions based upon safety and the criticality of a facility’s operations. A Power System Risk Assessment facilitates the development of a proposed maintenance schedule specific to a facility’s power distribution system. In addition, cost estimates are provided to help management develop a budget to carry-out the maintenance activities.

 

 

 

Fran Waterers full article on ‘Mintnance Contrats Can Improve Reliability, Safety' is one of the topics in Plant Engineering’s Forecast issue, which will be published in mid-February. To receive the digital edition of Plant Engineering in time for the Forecast issue, which also will feature the 2011 Plant Engineering Salary Survey, click here:



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.