Ole Miss Wins Big with On-Site Generation and Load Curtailment

Like all universities, Mississippi is always interested in keeping costs down. So when they learned of a load curtailment initiative introduced by the Tennessee Valley Authority (TVA) that would allow it to reduce its electricity costs, school administrators were eager to participate. TVA's load curtailment plan is simple.

09/01/2003


Like all universities, Mississippi is always interested in keeping costs down. So when they learned of a load curtailment initiative introduced by the Tennessee Valley Authority (TVA) that would allow it to reduce its electricity costs, school administrators were eager to participate.

TVA's load curtailment plan is simple. In exchange for granting TVA the right to cut off power to the university during peak demand times for up to 72 hours per year, the university is awarded reduced kW and kWh rates on its overall power usage—more than $1 million in annual savings.

The load curtailment plan gave the university a way to save on its electrical bills. But it created a new challenge: providing reliable power to the campus while TVA curtailed its power supply.

Fisher & Arnold, Inc., Memphis, Tenn. was contracted to design and build an on-campus generation facility. At a cost just under $7 million, the new facility houses 10 diesel generators with a maximum generation capacity of 20 megawatts. The facility also has two empty bays allowing for future capacity growth up to 24 MW. According to project manager Chet Puckett, the facility could power the entire campus for up to three or four days.

The system can function in several modes: island mode, where it provides all the power necessary while the campus is completely off-line from the utility; baseload mode, where it provides power supply in conjunction with the utility; and import/export mode where it can provide power back to the utility's electrical grid.

An energy-management system is another crucial control element within the facility. This system is comprised of three meters located on a relay panel in the switchgear and a server PC running the software package. Each meter fulfills a different function: measuring the overall load requirement, monitoring the power produced by the generators and tracking incoming power from the utility.

"The meters are a small but key part in the system," notes Puckett. "The information they provide allows the whole system to react quickly to any interruption in power from the utility, whether or not it is scheduled."





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me