NPN transistor added to high-performance bipolar power transistors

STMicroelectronics' 3STR1630 is an NPN transistor that offers a combination of high current capacity, collector-emitter blocking voltage and ultra-low collector-emitter saturation voltage.

05/09/2011


STMicroelectronics has introduced the first member in a new family of high-performance bipolar power transistors. The new transistors offer a combination of high current capability, collector-emitter blocking voltage and ultra-low collector-emitter saturation voltage, making them ideal for use in LED drives, motor and relay drives and dc-dc converters, according to STMicroelectronics.

The 3STR1630 is an NPN transistor manufactured using a new low-voltage planar technology. The planar technology incorporates a double-metal process that allows the cell density to be almost doubled without requiring the use of sophisticated photolithography equipment.

In addition to increasing the current capability by about 50 percent for the same die size, the double-metal process enables transistors with Vceo ratings up to 100 V, higher working switching frequencies (up to 300 kHz), and a 40% reduction in Vce(sat).

The first member of the new family, the 3STR1630, has a minimum BVCEO of 30 V, offering a compromise between a 28 V blocking voltage capability and minimum Vce(sat), with an equivalent on-resistance of only 100 milliOhms at hFE figure of 50. In addition, it can handle a continuous current as high as 6 A while being housed in a small outline SOT-23 package.

www.st.com

STMicroelectronics

- Edited by Amanda McLeman, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.