Northern California Greenfield Data Center

New construction; Northern California Greenfield Data Center; Morrison Hershfield

08/15/2013


Northern California Greenfield Data Center Project Photo Rendering. Courtesy: Morrison HershfieldEngineering firm: Morrison Hershfield
2013 MEP Giants rank:
92
Project:
Northern California Greenfield Data Center
Address:
California, United States (confidential client)
Building type:
Data center
Project type:
New construction
Engineering services:
Code Compliance, Electrical/Power, HVAC, Lighting
Project timeline:
January 2012 to October 2014
Engineering services budget:
$65,000
MEP budget:
$1.2 million

Challenges

As with any project of this size, the engineers are faced with many challenges. A representative challenge, as well as a good example of Morrison Hershfield's ability to innovate in order to save its client's money, is the HVAC system for the data center. The client had strict standards for reliability that Morrison Hershfield needed to adhere to, but the client challenged the to be creative in order to provide a system that met the N+N reliability requirements but had a lower total cost of ownership than the traditional systems that would be deployed.

Solutions

Morrison Hershfield's design incorporated chilled water CRAH units with EC fans. The CRAH EC fans’ energy consumption is reduced by 83% when operating at 50% speed as opposed to 100%. Morrison Hershfield developed a detailed sequence of operations which capitalized on the requirement of N+N CRAHs and the partial load efficiencies of the EC fans. The system will operate all units at 50% capacity. The design is incrementally scalable, and this simple approach to this system operation will save substantial energy costs over the life of this facility.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me