NFPA Conference & Expo Post-Show

The National Fire Protection Assn. World Safety Conference and Expo took place June 3 to June 7 at the Boston Convention & Exhibition Center. Below is a sample of some of the extinguishants that were featured. See the M/E Roundtable on p.23 for further insights into extinguishants. Clean agent fire suppression system is available that is non-synthetic, made from nitrogen, argon and carb...

07/01/2007


The National Fire Protection Assn. World Safety Conference and Expo took place June 3 to June 7 at the Boston Convention & Exhibition Center. Below is a sample of some of the extinguishants that were featured. See the M/E Roundtable on p.23 for further insights into extinguishants.

Clean agent fire suppression system is available that is non-synthetic, made from nitrogen, argon and carbon dioxide. Upon discharge, the extinguishant floods the room, remaining suspended to suppress fires quickly and effectively. It is free of residues and corrosive by-products that may produce further property damage. In performance testing, the product exceeded the NFPA Standard 2001 allowance of 1-minute discharge, with documented extinguishments of 22 seconds for a Class A fire and 17 seconds for a Class B fire. (Inergen by Ansul) www.ansul.com #7

Fire suppression fluid balances the need for human safety and low environmental impact. It features zero ozone-depletion potential, an atmospheric lifetime of five days and a global warming potential of one day. The fluid meets Halon replacement regulations and leaves no residue. The fluid, which is stored as a liquid, becomes a gas upon discharge, and is therefore easier to handle and store, the manufacturer says. (Novec 1230 Fire Protection Fluid by 3M) www.3M.com #8

Clean agent fire extinguishants are non-conductive and non-corrosive and are safe to use in facilities containing high-value electrical equipment. Because the family of four extinguishants does not leave behind residue, it helps minimize costly post-fire cleanup and business downtime. The family is designed to replace and eliminate the need for Halon in the protection of people and high-value assets. Unlike Halon, these extinguishants do not contain chlorine or bromine and therefore have zero ozone-depletion potential. (DuPont FE by DuPont) www.dupont.com #9

Fire suppression system includes detectors, control unit, agent storage cylinders, piping and discharge nozzles. The system is computer calculated to provide system discharge within 10 seconds. The fluid can be gravity fed for easy recharge, and the system extinguishes fire through heat absorption and not oxygen reduction. (Kidde Engineered System by Kidde Fire Systems) www.kiddefiresystems.com #10





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me