New Products

Steam turbine installs in a high-pressure steam distribution system in parallel with existing pressure-reducing valves to drive an electric generator. Components include a high-efficiency turbine, epicyclic speed-reduction gear and 460-volt induction generator. The system can produce 275 kW of electrical power.

08/01/2006


Steam turbine installs in a high-pressure steam distribution system in parallel with existing pressure-reducing valves to drive an electric generator. Components include a high-efficiency turbine, epicyclic speed-reduction gear and 460-volt induction generator. The system can produce 275 kW of electrical power.(Microsteam by Carrier) www.carrier.com #6

Condensing boilers are available in six different sizes from 300,000 to 1 million BTUs per hr. capacity.pm to satisfy environmental requirements. (Modulex by AERCO) www.aerco.com #7

Pump station offers modular distribution for hydronic heating. Besides the circulator, the station’s components are 100% brass and come complete to supply high temp, radiant floor and DHW. There are three different low-temp modules for heating zones with motorized or thermostatic mixing valve and one module for high temp zones or boiler primary loop. (PAW by Solarnetix) www.solarnetix.com #8

UPS management software monitors and manages UPS systems for workstations, servers, networks, data centers and facilities. One application includes automatic model detection, sequential shutdown, stealth mode operation and a cost calculator. The other is enterprise-wide UPS monitoring software that allows administrators to monitor multiple UPS and other power components. (LanSafe and PowerVision by Eaton) www.powerware.com #9

Ballast checker tool identifies ballast type to confirm ballast status and pinpoint lighting upgrade opportunities. When pointed at a fixture, the device turns green if the light source is powered by a high-frequency electronic ballast, orange if it’s powered by a magnetic ballast. It can also be used to verify that a fixture has been installed with an electronic ballast post-installation. (Ballast Checker by Advance) www.ballastchecker.com #10

Fire-rated poke-throughs install in a 4-in. core hole. The FRPTs include a “step-down” feature, enabling wiring, installation and removal, if necessary, from the floor above. Also included on the model is a subplate that incorporates two rectangular openings with up to six-port multi-service or 12-port all-communication service for power and/or data. (SystemOne by Hubbell) www.hubbell-wiring.com #11





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me