New Products: Smoke- and Fire-Alarm Technology

10/05/2005


Integration technology for fire-alarm panel platform integrates it with security management software. The integration of the firm’s 4100U and C%%POINT%%CURE 800/8000 represents a significant advancement in the ability to serve customers looking for integrated, enterprise-wide solutions. For more information about systems from SimplexGrinnell, click here .

Weatherproof fire-alarm appliances, including strobe, audible strobe, audible horn and multitone strobe appliances, provide enhanced resistance to temperatures ranging from -31°F to 150°F (-35°C to 66°C) and are rated for 75 candela @ -35°C. All appliances also meet or exceed the latest requirements of NFPA 72 (National Fire Alarm Code), UL Standard 1638 (Standard for Visual Signaling Appliances), and UL 464 (Standard for Audible Signaling Appliances).

For more information about weatherproof appliances from Wheelock, click here .

Combination Smoke and Carbon Monoxide Alarm incorporates advanced electrochemical sensing CO technology and the industry’s first true gas-sensor testing feature. Sensor diagnostics are said to provide a higher level of protection due to unique self-testing capability, which verifies that the carbon monoxide sensor is working properly and warns when the sensor is nearing the end of its service life. For more about Firex 12000 from Invensys, click here .

Selectable output wall-mount horns, strobes and horns/strobes are said to offer average current draws that are lower than conventional fixed-candela products, as well as lower than similar selectable candela products. Since less current is consumed, even more devices per loop can be connected, resulting in a lower installed cost. All strobe and horn/strobe models incorporate a new patent-pending voltage booster design that has a more consistent flash bulb voltage over the range of candela selections. For more about SpectrAlert from System Sensor, click here .





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me