New Products for Electrical Systems

12/19/2006



Two-compartment recessed floor boxes provide power and communications services in open spaces or directly to a workstation as a furniture feed box. The floor box can be installed in either concrete or wood floors. A lightweight slab-on-grade version features a fusion-bonded epoxy finish that is applied to the standard steel box, which eliminates the need for a costlier cast iron box. For more about the RFB2 Series by Wiremold/Legrand, click here .

Medium-voltage adjustable-speed drives are specifically designed for outdoor mounting in remote locations or where a building does not exist. This drive is designed to withstand extreme weather conditions, such as heat and direct sun, by incorporating a unique enclosure design and power section topology. The device is two enclosure types married together. The transformer section is convection cooled. There are no moving parts, and heat is eliminated through passive vents at the top of the drive. The inverter section is forced-air-cooled and only uses non-CFC cooling components. For more about MTX drives from Toshiba, click here .

Mini cable manager for tight spaces and small cable runs is a hand bendable cable conveyance that can mount to any surface (horizontal, vertical or angled).Built-in mounting rings are spaced to accommodate common stud spacing. It is an ideal cable conveyance for residential, audio/visual, sound/security, office environments, hospitals, and schools. For more about Snake Race from Snake Tray, click here .


Energy-efficient low-voltage transformers are designed to reduce energy consumption and costs for end users, while also addressing the impending federal government mandate requiring that all transformers manufactured after Jan. 1, 2007, meet new standards for increased energy efficiency. For more about Lean Power transformers from SquareD, click here .





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me