New Products for Controls and Automation

09/05/2006


BACnet service tool gives user field access to controller point information. The tool runs on a Windows Pocket PC or laptop and automatically discovers and edits BACnet devices from third parties as well as the manufacturer’s lines of controllers. It provides multiple displays of the entire BACnet system, including objects within the device, and detailed views of the BACnet properties of selected objects. Technicians can edit and change values, set descriptions and more. For more about Roam I02 from TAC, click here .

Control device provides full capacity modulation for all sizes of direct-expansion air conditioning systems that use R-410A non-ozone-depleting hydrofluorocarbon refrigerant. The control continuously and automatically matches AC system capacity/output to changing load conditions. It is claimed to dramatically improve humidity control without overcooling the space and eliminate common maintenance problems associated with excess system capacity such as coil icing, liquid slugging, and excessive compressor cycling. For more about APR Control by Rawal, click here .

Fan-coil thermostat is low-voltage Lontalk communicating device that is said to offer reduced installation cost and delivery time by reducing wiring. Units are pre-programmed with six onboard sequences of operation. The device is suitable for two- and four-pipe applications with or without local reheat. For more about VT7300 series by Viconics, click here .

Room pressurization control is said by its manufacturer to be suited to VAV controller applications where stable directional airflow into or out of the space is critical. The device also performs occupancy and HVAC emergency mode control either locally or through network commands from the BAS. For more about Traccel by Phoenix Controls, click here .





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Boiler basics; 2017 Product of the Year winners; Manufacturing facilities Q&A; Building integration; Piping and pumping systems
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me