New connectors for industrial lighting connections

Wago Corporation's new connectors for its Winsta series speed electrical connections for industrial lighting.

08/04/2011


WAGO Corporation added three new connectors to its Winsta Mini and Midi Connection Systems. The MINI 890 Series received 4- and 5-pole units for space-restricted applications. Mid-range MIDI 770 Series added a new 2-pole connector, enabling MIDI to continue providing the broadest array of connectors for standard installations.

Mini 890 Series:

Winsta Mini’s 4- and 5-Pole Plug and Socket Connectors join existing 2- and 3-pole connectors. Engineered for modern lighting fixtures, such as LED luminaires, Winsta Mini is rated up to 600 V and 14 A (16 AWG). Winsta Mini carries a UL Current Interruption Rating of 5 A, 600 V for disconnection under load, providing safe swap-out of components such as drivers or LED modules.

Midi 770 Series:

Aimed at high-bay fluorescent fixtures and other electrical installations, a new 2-Pole Plug and Socket Connectors join Winsta Midi 3-, 4- and 5-pole units. The plug-and-play 2-Pole connectors are rated up to 600 V and 20 A (12 AWG) and carry a UL Current Interruption Rating of 10 A, 600 V. Thus, Midi is apparently a safe means of disconnection for hot-swappable components such as pumps and small motors. MIDI options include snap-mount, flying lead and distribution connectors that enable use of pre-configured assemblies, streamlining on-site installations.

Winsta Pluggable Connection Systems:

Winsta Midi reportedly accommodates conductors AWG 20–12 up to 20A; Mini accommodates AWG 22–16 up to 14A. Both feature 2- to 5-pole plug and socket modules for cord-end or snap-in panel mounting; various pluggable distributors (e.g., T-connectors, H-connectors); as well as distribution boxes. Safety features: Touch-proof housings and connections that are 100% safeguarded from mismating — coding is optional. Mated pairs incorporate optional Positive Locking to ensure halves stay properly connected.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me