Nanoflowers improve ultracapacitors

A novel design could boost energy storage.

09/22/2008



Imagine a cell-phone battery that recharges in a few seconds and that you would never have to replace. That's the promise of energy-storage devices known as ultracapacitors, but at present, they can store only about 5% as much energy as lithium-ion batteries, according to a story in MIT’s Technology Review . An advance by researchers at the Research Institute of Chemical Defense, in China, could boost ultracapacitors' ability to store energy.

A capacitor consists of two electrodes with opposite charges, often separated by an insulator that keeps electrons from jumping directly between them. The researchers have developed an electrode that can store twice as much charge as the activated-carbon electrodes used in current ultracapacitors. The new electrode contains flower-shaped manganese oxide nanoparticles deposited on vertically grown carbon nanotubes.

The electrodes deliver five times as much power as activated-carbon electrodes, says Hao Zhang, lead author of the Nano Letters paper describing the new work. The electrode's longevity also compares with that of activated-carbon electrodes, Zhang says: discharging and recharging the electrodes 20,000 times reduced the capacitor's energy-storage capacity by only 3%.

So far, ultracapacitors have been limited to niche applications that require high power and quick, repetitive recharging. For example, the devices provide quick bursts of power to buses, trucks, and light-rail trains over short stretches, and braking replenishes them. If they could store more energy, however, they could be a powerful, long-lasting replacement for batteries in hybrid-electric vehicles and portable electronics.





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me