Multi-touch panel PC series for PLC and motion control applications

Beckhoff Automation's fanless CP26xx Panel PC series has multi-touch functionality is designed for use in PLC and motion control applications in addition to running HMI software.

02/04/2014



With multi-touch functionality and 1 GHz ARM Cortex A8 CPU, the CP26xx Panel PCs from Beckhoff are ideally suited for small and medium-sized PLC and motion control applications. Courtesy: Beckhoff AutomationBeckhoff Automation's fanless CP26xx Panel PC series has multi-touch functionality is designed for use in PLC and motion control applications. This feature-filled solution is ideal for control of small to medium-sized machines. The ARM Cortex A8 processor used in the CP26xx Panel PC series has a hardware-based floating point unit, which makes floating point operations (Real, LReal) significantly faster.

Subsequently, this powerful Panel PC series can be used for motion control applications in addition to running the HMI software. TwinCAT automation software from Beckhoff turns the Panel PC into an all-in-one HMI, PLC and motion control system. The CP26xx Panel PC features a 1 GHz ARM Cortex A8 CPU with access to 1 GB internal DDR3 RAM memory. The standard operating system is Microsoft Windows Embedded Compact 7.

Additionally, a 256 MB Micro SD card is included as standard and up to 4 GB are optionally available. A 128 kbyte NOVRAM ensures fail-safe storage of TwinCAT process data. Also available is an on-board 10/100BASE-T Ethernet adapter, an EtherCAT adapter with RJ-45 connector and an RS-232 interface with two USB-2.0 ports. The aluminum panel housing, with high quality glass front, offers IP 65 protection at the front and IP 20 in the back. Users have a choice of eight different multi-touch TFT displays in sizes between 7 in" and 24 in", as well as 4:3, widescreen, landscape or portrait formats.

Beckhoff Automation

www.beckhoff.com 

- See more Control Engineering industrial PC products.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me