Multi-axis conformal coating machine handles high volume throughput

Baldor Ethernet-compatible Powerlink servos simplify machine build in small packages.

Baldor Electric Company

02/16/2011


ACR MACCS 400An advanced real-time Ethernet motion control system has helped Advanced Coating Robotics (ACR) to create a new conformal coating machine that reportedly combines exceptional three-dimensional spraying accuracy with very high throughput.

The multi-axis system is based on Baldor Electric motion control products, with three axes making use of the company’s Ethernet-compatible PowerLink servo drives. Baldor said key reasons behind the choice of this motion control technology were the flexibility of Baldor’s motion control software, the ease with which real-time interpolated control could be applied across the machine’s five-axis servo and stepper driven motion, and the simple plug-together system building approach offered by the Ethernet-based modules.

ACR's new MACCS 400 machine provides a means of selectively applying protective conformal coatings to printed circuit board (PCB) mounted components, and can accommodate both inline and batch processing operations. Capable of coating PCBs as large as 500 x 480 mm – with on-board components as high as 90 mm – the programmable machine uses an advanced five-axis motion control system to purportedly combine high-speed throughput capabilities with ultra-precise spray head positioning to an accuracy of 25 microns.

Formed in 2009, with the specific intention of developing highly automated solutions for applying conformal coatings to electronic components, ACR is a collaboration between SCH Technologies, a conformal coating company, and specialist automation designers SMS Machines & Automation Ltd.

MACCS 400 is a self-contained, free-standing machine with a small 1.4 m2 footprint. It is allegedly capable of completely autonomous operation, or can be equipped with chain conveyors and form part of an integrated PCB production line; the machine is fully compliant with the SMEMA (surface mount equipment manufacturers association) mechanical and electrical interface standards.

The X and Y axes of the machine’s motion control system are based on a novel ‘H-belt’ actuator, driven by two Baldor BSM servomotors linked to Baldor MicroFlex e100 drives. The two motors are static – they occupy fixed positions at the bottom of the ‘H’ – and jointly act on one belt. The advantage of this approach is that the motors do not contribute to the load inertia, and therefore permit very fast and accurate movement – the machine can accommodate X-Y velocities as high as 800 mm/second. The Z axis controls the above-board height of the spray head, and is driven by a third BSM servomotor and MicroFlex e100 drive. All three drives are very tightly synchronized to reportedly facilitate high speed Cartesian movement of the spray head, the angle and orientation of which are controlled by two rotary axes, driven by Baldor stepper motors.

All five electrical axes on the MACCS 400 are controlled by a Baldor NextMove e100 controller, using full interpolation to allow smooth high speed tangential moves. Overall control of the machine is handled by ACR’s proprietary coating software, which runs under Microsoft Windows XP on a built-in host PC, equipped with a large HMI (human-machine interface). The coating software reportedly provides a highly intuitive graphical user interface and is written in the VB.NET object-oriented programming language.

The MACCS 400 can apply a wide range of conformal coatings, including Parylene and many HumiSeal products, and offers a choice of cartridge or pressure vessel feed. Standard features include an integral camera for manual alignment, a remote teach pendant, and built-in purge and solvent cups for flushing. The machine also offers numerous optional facilities, such as multiple spray heads, fluid viscosity control, a bar code reader and a laser pointer.

www.baldor.com

Baldor Electric Company

- Edited by Gust Gianos, CFE Media, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.