Motion controller with Ethernet, takes encoder inputs up to 15 MHz

Enhancements to this motion controller, the latest product in a series, includes Ethernet 100Base-T, a USB 2.0 port, higher speed performance, larger program memory, and more. It can close a loop in 62 microseconds.

09/09/2010


Galil Motion ControlGalil Motion Control introduces the DMC-41x3 motion controller series, the latest product in the Econo series, designed to deliver high performance at a lower price. Enhancements include Ethernet 100Base-T, a USB 2.0 port, higher speed performance, larger program memory, analog inputs, and optically isolated I/O. Compared to the older DMC-21x3 Econo Ethernet controller, the new controller offers many speed improvements, can accept encoder inputs up to 15 MHz,  can close-the-loop as fast as 62 microseconds, and offers twice as much memory for user-programs and arrays. The DMC-41x3 is available as a card-level product or packaged in a metal enclosure.

The DMC-41x3 operates stand-alone or interfaces to a PC with Ethernet 10/100Base-T or USB. An auxiliary RS232 port is also provided. The product is available in one through eight axis formats, and each axis is user-configurable for stepper or servo motor operation. The controller can be connected with external drives of any power range, or with Galil’s multi-axis (500W per axis) servo drives or 60V, 3A microstepping drives. Drives install directly onto the DMC-41x3 controller, fitting inside the metal enclosure to save space, cost and wiring. Standard I/O includes 16 optically isolated inputs and outputs for the one to four axis models, and 32  I/O for the five to eight axis models.  Other controller features include PID compensation with velocity and acceleration feedforward, memory for user programs, multitasking for simultaneously running up to eight programs, and I/O processing for synchronizing motion with external events. Modes of motion include point-to-point positioning, position tracking, jogging, linear and circular interpolation, contouring, electronic gearing, ECAM and PVT.

http://www.galilmc.com/products/dmc-41x3.php

DMC-41x3 Motion Controller Series

- Also from Control Engineering:

Tutorial on common motion control and I/O problems;

Motion controller aids fine art of carpet cutting; and

Targeting Tumors with Motion Control.


- Edited by Renee R. Bassett for Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me