Molded case circuit breaker

The PowerPact B-frame circuit breaker is designed to offer robust power protection in a compact size and 'efficiency that clicks' to the work day.

12/29/2016


The PowerPact B-frame circuit breaker is designed to offer robust power protection in a compact size and efficiency that clicks to the work day. Courtesy: Schneider ElectricThe PowerPact B-frame circuit breaker is designed to offer robust power protection in a compact size and "efficiency that clicks" to the work day. The 125 A B-frame circuit breaker is the smallest Square D molded case circuit breaker offered in the PowerPact range. It utilizes economical, thermal magnetic sensing elements and is designed to be flexible and offer integrated DIN rail and back-pan mounting capabilities without extra adapter brackets. A wide variety of external mechanical operators for control panel applications complement field-installable electrical accessories. PowerPact B circuit breakers also feature EverLink creep-compensating lug technology. This spring-based power terminal system ensures a lasting connection by mitigating the loosening effects of heat cycling or vibration. The lugs are UL listed for use directly with stranded and fine-stranded wire up to Class K. EverLink lugs are even offered with optional built-in control wire terminals.

Schneider Electric

www.schneider-electric.us 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me