Modular water-to-water series

The Tranquility Modular Water-to-Water (TMW) Series by ClimateMaster is available in 360 and 600 sizes.

03/27/2012


ClimateMaster introduces the Tranquility Modular Water-to-Water (TMW) Series in 360 (30 tons) and 600 (50 tons) sizes. The TMW series can be used for radiant floor heating, snow/ice melt, chilled water for fan coils, hot/chilled water for make-up air, and many other types of HVAC applications.  The TMW 360-600 has advanced digital controls for BAS interface, four LEDS for unit status, and compressor isolation switches. Other features include: front and back service access panels that allow for side-by-side installation; larger capacity, requiring fewer units per job site; staggered top water connections for ease of manifolding multiple units; and DDC controls with 11 safety protections for the refrigeration circuits.  

www.climatemaster.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me