SEARCH Archives
Loading
Sponsored by:

Mini-slide with integrated electrical drive saves time

The MSC-EL mini-slide by Rexroth saves time, simplifies start-up, improves safety, cleanliness in work areas

01/12/2011


The new, ready-to-install MSC-EL mini-slide with integrated electrical drive from Rexroth reportedly reduces the time required to plan, install and start up customized handling systems. Ideal for small pick-and-place applications, the new MSC-EL was designed to offer proven Rexroth precision and performance in applications requiring multi-point positioning control in the same size package as the pneumatic MSC version.

Available initially in two sizes, the MSC-EL-12 and MSC-EL-16 can be ordered in standard lengths and are capable of travel to any position from 50 mm to 150 mm (size 12 = 80 mm). Each module has the same mounting and cross-section dimensions as the pneumatically driven MSC mini-slide. CamoLINE connectivity resulting from the Easy-2-Combine interface provides for quick connection without the need for auxiliary adapter plates and extensive adjustment.

A brushless, 24 V dc motor efficiently powers the new MSC-EL. With an integrated belt drive gear as well as a ball screw assembly and ball rail system lubricated for life, the maintenance-free unit provides high performance within compact dimensions. The maximum load for size 12 is 4 kg for horizontal motion and 2.0 kg for vertical motion applications. The maximum load for size 16 is 5 kg for horizontal motion and 2.5 kg for vertical applications. An optional holding brake is available for vertical installation.

To save time and simplify start-up, basic axis-specific parameters have been pre-programmed in the sequence control system for the drive amplifier. Parameterization of up to 15 positions takes place conveniently via PC. With its precision ball screw drive, the mini-slide is able to achieve repeatable positioning of 0.01 mm and can be integrated into many automated structures with its digital I/Os. The drive controller also features a CANopen interface. Pre-assembled cable sets and standard electrical components reduce start-up time substantially.

The enclosed unit improves safety and cleanliness in the work area, which is particularly important for applications in the semiconductor, automation, automotive, medical equipment, and electronics industries. Easy attachment of Rexroth rotary modules and mechanical grippers allows for a wide range of handling tasks.

www.boschrexroth.com Rexroth



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.