SEARCH Archives
Loading
Sponsored by:

Mini dc gear motors develop high torque

Nidec Copal’s OD miniature dc gear motors develop high shaft torque, speeds ranging from 1400 rms down to 40 rpm

12/15/2010


Nidec Copal’s new RoHS family of four 12 mm (0.472-in.) OD miniature dc gear motors develop high shaft torque ranging from 0.28 oz-in. (LA 12G-344 VW) up to 6.94 oz-in (LA 12G-344 VT). Rated shaft speeds range from 1400 rpm down to 40 rpm. The metal spur gears incorporated in the geartrain permit high shaft torque from these incredibly tiny dc gear motors. The gear motor’s axial length is 1.023-in. Input voltage levels range from 4.5 V dc to 6.0 V dc. Rated current levels for the 4 LA 12G-344 models do not exceed 250 milliamps. Nidec Copal can provide many windings.

www.nidec-copal-usa.com

Nidec Copal

-

Also see:

Motor tutorials at www.controleng.com/videos



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.