Microchannel Coils Have Now Been Adapted to HVAC Applications

02/06/2006


Carrier Corporation, a unit of United Technologies Corp., has announced the achievement of world class efficiencies of 10.9 EER full-load and 15.4 part-load on air-cooled chillers with non-ozone depleting HFC-134a refrigerant by utilizing microchannel coil technology.

“Microchannel coil technology is widely used in the automotive industry to increase heat transfer efficiency while providing enhanced reliability through improved corrosion resistance,” said David Sabatino, product manager, Carrier air-cooled chillers. “Now, microchannel coils come standard with an industry exclusive three-year coil warranty on all of our Aquaforce models ranging from 80 to 500 tons.”

Carrier claims that in addition to the chiller’s efficiency and improved corrosion resistance using the new microchannel coil technology, the chiller is now even more environmentally sound.

Sabitino explains that the adaption of microchannel coil technology to the commercial HVAC industry was only possible after a boost in efficiency and standardization of the technology.





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me