Medium voltage AC drive is compact, saves energy

Yaskawa's MV1000 medium voltage ac drive family use a modular, compact design for energy savings and are compatible with the 1000 series low voltage ac drive products.

10/16/2013


Yaskawa's MV1000 medium voltage AC drive family use a modular, compact design for energy savings and are compatible with the 1000 series low voltage AC drive products. Courtesy: YaskawaYaskawa's MV1000 medium voltage ac drive family are designed for energy savings and improved process control and are compatible with Yaskawa’s 1000 series low voltage ac drive products. Yaskawa’s Smart Harmonics Technology reduces input Total Harmonic Distortion (THD) to less than 2.5% without filters which exceeds the requirements of IEEE519-1992 by almost 50%. This technology also provides galvanic isolation between power input and output.

The MV1000 uses two 5 voltage step bridges per phase to generate a 17-level line-to-line voltage output delivered to the motor. The near sinusoidal waveform results in low THD voltage, low torque ripple, and excellent low speed torque, all motor friendly features, again without the need for output filters. 

Several motor control modes are available to fit a wide range of applications: Open Loop Vector for smooth acceleration from low speed without an encoder, closed loop vector for demanding high performance applications, and synchronous motor control for retrofits to existing installations.

The MV1000 also features a compact modular design that facilitates transportation, installation, and maintenance. The design includes a transformer panel, power cell panel, control section, and cooling fans resulting in an MTBF (mean time between failures) greater than 200,000 hours.

These medium voltage drives are further simplified by incorporating the same interfaces as Yaskawa 1000 Series low voltage drives. This includes the same digital operator, parameter structure, a medium voltage version of the Drive Wizard Plus software utility, various communication plug-ins and the same USB copy unit.

Yaskawa America Inc.

www.yaskawa.com 

- See more Control Engineering motor and drive products.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me