Mass flow controllers

20SLPM is a model of BASIS line of mass flow controllers that fits applications including sparging into liquids, sample dilution, and gas mixing applications.

05/18/2016


20SLPM is a model of BASIS line of mass flow controllers that fits applications including sparging into liquids, sample dilution, and gas mixing applications. Courtesy: Alicat ScientificAlicat Scientific's 20SLPM model of BASIS line of mass flow controllers fits applications including sparging into liquids, sample dilution, and gas mixing. Specifically designed for original equipment manufacture and process integration, BASIS is small footprint instrument, providing fast, accurate control of gas flow rates. BASIS family are suited for use in OEM gas analyzers, automated gas mixing on process lines, and anywhere basic mass flow-only control is required. A 100 ms control response enables BASIS to react in real time to upstream fluctuations. BASIS is available with the variety of multi-gas calibrations including Air, Ar, CO2, N2, O2, N2O; He, and H2 are also available in single-gas units.

Alicat Scientific

www.alicat.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me