Manufacturers’ focus on data centers: Automation and controls

Designing efficient and effective data centers and mission critical facilities is a top priority for consulting engineers. Three manufacturers share information about their company’s products and solutions.

01/15/2013


Participants

  • John Collins, Global Segment Director, Data Centers, Eaton Corp., Raleigh-Durham, N.C.
  • Jim Dagley, Vice President, Channel Marketing & Strategy, Johnson Controls Inc., Milwaukee, Wis. 
  • John Kovach, Global Head of Data Center Initiatives, Siemens, Buffalo Grove, Ill.

Automation and Controls

CSE: Integration of facilities is becoming more prevalent. How is your company/product meeting this need? Provide a recent project example.

Kovach: Integration is needed on many levels. We take a bottom-to-top integration approach and offer as many options as possible. One of the advantages we offer is the breadth of our portfolio and the corresponding depth of knowledge on facility best practices across the electrical and mechanical infrastructure. In addition to our own portfolio pieces, our compatibility partners for our APOGEE building automation system (BAS) include the leading names in fire, life safety, security, electrical, lighting, mechanical, and industrial systems. Customers’ options would include 700 systems/ devices, representing 200 different vendors and more than 70 different proprietary and standard protocols.

Dagley: Integration is everything right now, and we are not talking about two or three systems; our customers are expecting outcomes that require the integration of more than 20 systems, including the data center. A great example is Children’s Hospital of Pittsburgh, where we implemented an enterprise-level solution that not only reduced infrastructure costs associated with multiple networks, but also provided increased flexibility for future upgrades and additions. Through technology contracting, we managed all related subcontractors, serving as the single point of responsibility for the design and installation of the network and technological systems across all eight facilities on campus. The technology map comprises nearly 30 integrated systems including the building management system, security and fire, as well as a variety of third-party systems including local and wireless area networks, nurse call, electronic medical records, and many others.

Collins: Eaton is meeting this trend in two ways. First, we’ve recognized that interaction between various types of power equipment and airflow management strategies for different facility sizes and applications is all part of the design process, so we are designing and testing our entire portfolio of products to work as a unified system. We have also developed our Foreseer electrical power management system (EPMS) to integrate all electrical and mechanical equipment and usage metrics to be viewed from a single screen. Foreseer can also integrate the building management system (BMS), security systems, and fire alarm systems to enhance productivity and response time. For example, a customer with a 100,000+ sq ft “lights-out” data center can set up Foreseer as the “parent” system. The BMS and other systems can exchange more than 500 points of data every second with the parent EPMS, so any situation can be addressed in minutes. Additionally, the solutions’ analytic and trending features can be used to anticipate failures before they happen.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.