Managing Microbial Contaminants

Molds, fungi and bacteria are grabbing the attention these days when it comes to indoor-air quality (IAQ). Volatile organic compounds (VOCs) are still of concern-with over 300 VOCs identified and more being created all the time through the development of new building materials-but the public, and much litigation, has focused of late on microbial contaminants.

02/01/2001


Molds, fungi and bacteria are grabbing the attention these days when it comes to indoor-air quality (IAQ). Volatile organic compounds ( VOCs ) are still of concern-with over 300 VOCs identified and more being created all the time through the development of new building materials-but the public, and much litigation, has focused of late on microbial contaminants. For example, most of the IAQ concerns in schools have to do with molds.

A major problem for engineers who are called upon to address these IAQ issues is that there are no exposure standards for molds and mycotoxins. Consequently, the designer needs to have a good working knowledge of potential microbial contamination and its causes, whether for new projects or retrofits and remediation work.

Legionella is a topic in itself. Outbreaks of legionellosis have been traced to condensers and cooling towers, among other sources. An outbreak last year began in a cooling tower at the Melbourne, Australia, municipal aquarium and resulted in the replacement of water-cooled air conditioning with an air-cooled system.

Good design and maintenance can help prevent the bioaerosol contamination that leads to legionellosis. An American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) position paper on legionellosis makes the following suggestion: avoid piping that is capped and has no flow; control domestic water temperature to below 25

In addition, air intakes must be placed away from cooling towers and evaporative condensers, effective drift eliminators on cooling towers and condensers should be maintained; and air filters for outside air must be kept dry.

Controlling dampness

With molds, in particular, moisture is always the culprit. Consequently, design and maintenance of HVAC systems is particularly important in controlling the moisture that breeds molds. One manufacturer offers a single-liquid desiccant technology, known as dry cooling. While its primary function is dehumidification, it is also said to supply clean, dry air.

Ultraviolet bulbs inside air-handling systems are used to saturate a space with ultraviolet light, eliminating microbial contaminants. Custom units accommodate the space requirements of the heating or air-conditioning system.

Filters often provide the perfect medium for growing molds, and because keeping filters clean and in proper working order is the responsible of a building operating staff, it is important for design professionals to stress this in training.

Insulation inside ducts is also a source of moisture, and hence, of microbial contaminant growth. In some remediation projects, insulation inside ducts is removed and replaced with external insulation.

Design professionals should anticipate a continuing public concern about microbial contaminants.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me