Managing emergency power in mixed occupancy health care facilities

A growing trend within the health care industry is the use of mixed occupancies in a single building—such as medical offices, an ambulatory surgical center, and an emergency department.

06/28/2017


RTM Engineering Consultants has experience in health care design, encompassing more than 500 projects across 20 different states. RTM takes into account factors, such as local codes and facility constraints, to provide cost-efficient engineering solutions that increase staff and patient satisfaction.

A growing trend within the health care industry is the use of mixed occupancies in a single building—such as medical offices, an ambulatory surgical center, and an emergency department.

RTM has started projects building local healthcare sites that include medical offices, an ambulatory surgical center and and emergency department, responding to a recent trend for this type of facility. Courtesy: RTMassociates.comThere has been a transition within the industry. It’s a shift away from large full-scale hospitals; instead, community based sites are adding on an emergency department and perhaps a surgical center. These micro-hospitals don’t have full hospital functionality, but they can provide immediate care more locally in the community, which caters to those who want access to more personal care where they live.

The challenge in developing the engineering strategy for these buildings is that each space has different emergency power requirements. The engineering team must ensure that the facility is equipped with adequate emergency protection, while minimizing excess energy usage.

RTM will finish another facility by November 2017. Drexel Town Square in Oak Creek, Wisconsin, features a 130,000-square-foot health care facility; the main section is a medical office building offering outpatient services, with an ambulatory surgical center (ASC) suite. In a different part of the building, the facility will open an urgent care center, which will evolve into an emergency department in the future.

The medical office building and the ambulatory surgical center are classified as a B occupancy, generally used for medical offices or outpatient clinics. The urgent care center or emergency department, however has an I-2 occupancy classification, which is used for medical, surgical, psychiatric, nursing, or custodial care on a 24-hour basis for more than five people who aren’t capable of self-preservation. Because of these occupancy changes and each facility’s requirements, three separate emergency systems needed to be developed, powered by a single generator, to comply with the code.

Having an ambulatory surgical center and a medical office reside in the same building is pretty typical. The issue that needs to be addressed is that an ASC needs to be designed similar to a full-scale hospital. An office building isn’t required to have an emergency power system supplied by a generator, but an ASC is. And an ambulatory surgical center and an emergency department have similar emergency power requirements—with three branches of power for life safety, critical power, and equipment. But since they reside in different occupancies, they must have separate systems.

Though the medical office building isn’t obligated to have the three branches of power, only life safety capabilities (fire alarms, emergency lighting, etc.), RTM designed an optional standby power system using the on-site generator. This system manages power loads the facility prioritizes in an emergency, such as running the call center to contact patients.

This thorough attention to detail has long-term benefits for clients, resulting in critical operational cost and energy savings that can be applied to methods for increasing patient care.

A standard approach to this project would have ended with eight transfer switches, but following the code, four transfer switches were able to be eliminated to have only a total of four. This is equipment that costs a substantial amount of money, and they cut it in half. 

This article originally appeared on rtmassociates.com. RTM Engineering Consultants is a content partner of CFE Media. 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Boiler basics; 2017 Product of the Year winners; Manufacturing facilities Q&A; Building integration; Piping and pumping systems
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me