Machine vision cameras, controllers, software

High-performance NI 177x Smart Cameras, the NI CompactRIO embedded control and acquisition platform, and the NI Vision Development Module library are among machine vision tools from National Instruments. See link to vision-motion design tutorial.

04/25/2012


High-performance NI 177x Smart Cameras feature monochrome or color CCD image sensor options and a powerful Intel Atom 1.6 GHz processor for automated inspection applications. Courtesy: National InstrumentsThe high-performance NI 177x Smart Cameras feature monochrome or color CCD image sensor options and a powerful Intel Atom 1.6 GHz processor for automated inspection applications. The rugged mechanical design, including IP67 housing, M12 connectors, and lens cover, protects the cameras against harmful ingress of water (up to 1 m immersion) and dust. The cameras also include digital I/O lines (4 input, 4 output), an RS232 serial connection, Gigabit Ethernet connection, and VGA video output. Programming the cameras is accomplished using Vision Builder for Automated Inspection or the LabVIEW Vision Development Module, which both feature hundreds of built-in machine vision and image processing functions.

NI CompactRIO is an embedded control and acquisition platform, featuring a reconfigurable FPGA and real-time embedded controller, ideal for machine vision applications. It can connect to GigE Vision cameras and use the NI Vision Development Module libraryNI CompactRIO is an embedded control and acquisition platform, featuring a reconfigurable FPGA and real-time embedded controller. The new Multicore CompactRIO systems are ideal for applications that involve machine vision, including medical devices, autonomous robotics, and industrial monitoring. Using the dual gigabit Ethernet ports, you can connect to a wide range of GigE Vision cameras and perform fast, high-resolution image acquisition, and perform image processing in LabVIEW using hundreds of image processing algorithms in the NI Vision Development Module library. Multicore CompactRIO is available with LabVIEW Real-Time OS or Microsoft Windows Embedded Standard 7 (WES7). 

See integrate machine vision-motion design tutorial, linked below.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me