M&R Printing Equipment uses advanced servo, controller

Mitsubishi Electric Automation MR-J4 Servo and Q170 stand-alone motion controller help M&R Printing Equipment beat its own world record.

10/31/2013


Mitsubishi Electric Automation MR-J4 applies a high-speed servo control architecture to a dedicated execution engine. Speed frequency response is increased to 2.5 kHz, achieving the industry-leading level of speed, based on Mitsubishi Electric research asThe MR-J4 Servo and Q170 stand-alone motion controller from Mitsubishi Electric Automation helped M&R Printing Equipment beat its own world record. M&R was building on a 20-year history of working with the automation provider and prior success of using the Mitsubishi Electric Automation MR-J3 B Safety Servo Drive and HF-SP Motor used in its production Challenger III press. M&R Printing Equipment selected Mitsubishi Electric products for the M&R Challenger III D J4 press, confident that Mitsubishi Electric’s successor to the MR-J3 would meet its needs.

Mitsubishi Electric chose its MR-J4 Servo System for M&R’s high-speed concept press because it provides fast index time, quick setting time, rapid closed loop control, and extremely accurate positioning control—all features that M&R required in its new press in to beat the T-shirt printing speed record.

With a 2500 Hz frequency response speed time, MR-J4 is one of the fastest servos, Mitsubishi Electric Automation said. This feature reduces settling times to less than 2 milliseconds (msec), maximizing machine performance and throughput for machine buildeM&R used Mitsubishi Electric’s Q170MCPU stand-alone motion controller in its Challenger III production press and was impressed with its superior performance. For the sophisticated demands of M&R’s concept press, Mitsubishi Electric recommended its Q170MCPU motion controller with built-in motion and logic control, as well as a built-in Ethernet network. With the Q170MCPU motion controller and PLC, motion control data is shared via the built-in EtherNet/IP port. Designed to handle the most complicated high-speed applications, the Q170MPCU includes built-in power supply, an external encoder interface, and high-speed registration inputs.

“Mitsubishi Electric maintains the legacy of its products, which is important to our future development needs,” said M&R’s chief electrical engineer, Bo Biel. “M&R and Mitsubishi Electric share the same vision for the development of our products.”

Pre-event testing at the FESPA trade show aims to ensure on-site setup will support a run at the record. Courtesy: Mitsubishi Electric AutomationTesting new technologies for future product development improves performance and increases production output. “And, we know that Mitsubishi Electric will be there to support our development needs f5, 10, or 30 years from now,” Biel concluded.

- Greg Hookings, marketing communication manager, Mitsubishi Electric Automation. Edited by Mark T. Hoske, content manager CFE Media, Control Engineering and Plant Engineering, mhoske@cfemedia.com. 

ONLINE

See also, application article for more details and application photos: Printer breaks world record with advanced servo, motion controller, below

See a demo video showing the machine running prior to the record-setting run. Additional information follows, below.

- Mitsubishi provides information about the prior record setting machine

Mitsubishi provides more information about the MR-J4



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me