Low-voltage switchgear for mission critical environments

Low-voltage switchgear technology designed to extend type 2B arc-resistant ratings with the instrument and breaker secondary door open provides centralized control and protection for low-voltage power distribution equipment.

06/02/2015


Low voltage switchgear technology designed to extend type 2B arc-resistant ratings with the instrument and breaker secondary door open provides centralized control and protection for low-voltage power distribution equipment.Low-voltage switchgear technology designed to extend type 2B arc-resistant ratings with the instrument and breaker secondary door open provides centralized control and protection for low-voltage power distribution equipment. The new switchgear is engineered to improve uptime for data center, oil and gas, mining, utility, and other mission critical industrial applications. The new switchgear design allows access to the control switch and indicator lights located on the breaker secondary doors without opening the main breaker door. Eaton's two-part design allows the circuit breaker door to remain closed while accessing control wire, and retains the C37.20.7 arc-resistant rating during routine maintenance to simplify access to circuit breaker secondary terminals and reduce unplanned downtime. In compliance with NFPA 70E, and as defined by the American National Standards Institute (ANSI) C37.20.7 standard, the arc-resistant low-voltage switchgear carries a hazard risk category of zero for circuit breaker operation with doors closed and latched.

Eaton

www.eaton.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me